Averstar Chemical Editorial Team Updated September 22, 2026
FAO/WHO Pesticide Specifications and CIPAC Methods: A Buyer Guide

FAO/WHO pesticide specifications and CIPAC methods are often cited in quotations and certificates, but they serve different functions. The specification defines identity and acceptable quality characteristics. The analytical or physical test method defines how those characteristics are measured. A buyer needs both pieces to make a result reproducible and enforceable.
The framework is especially valuable in international sourcing because it gives suppliers, laboratories, buyers and authorities a shared technical language. It does not replace registration, a label or market-specific legal requirements.
Key Takeaways
- A specification states what quality is required; a method states how a parameter is measured.
- FAO/WHO specifications can support contracts and regulatory quality control but are not product registrations.
- Method number, version, units, sampling and acceptance limit should be agreed together.
What an FAO/WHO Specification Covers
FAO states that pesticide specifications are intended to support confidence in purchase and use and can provide a normal quality standard for contracts. The official pesticide specifications page links specifications, manuals, templates and supporting quality-control guidance.
A specification may address description, active ingredient content, relevant impurities, acidity or alkalinity, water content and formulation-dependent performance tests. The applicable clauses differ by formulation. A water-dispersible granule, soluble concentrate and suspension concentrate should not be given the same generic test list.
What a CIPAC Method Adds
CIPAC methods provide standardized procedures for active ingredient analysis and formulation properties. A method reference can define apparatus, standard water, sample preparation, timing, calculation and reporting. Those details reduce the chance that buyer and supplier laboratories perform nominally similar tests in incompatible ways.
Method references must still be precise. Record the full method designation and current version or handbook location where the contract requires it. If a laboratory proposes an internal method, ask for validation or a documented comparison with the agreed reference method before treating results as interchangeable.
Old Procedure and New Procedure Specifications
FAO's Registration Toolkit explains an important distinction. Specifications developed under the older procedure were generally written for broad application, while new-procedure specifications apply to products from manufacturers whose supporting data were evaluated. Buyers should therefore check the evaluation and manufacturer scope instead of assuming that every product with the same active ingredient is covered.
How to Write a Test Clause for Procurement
- Identify the exact active ingredient, concentration basis and formulation code.
- Name the specification or internally agreed requirement and its date or version.
- Name the analytical or physical test method and reporting units.
- State the acceptance limit, rounding rule and whether it applies before or after storage testing.
- Define sampling, sample retention, dispute testing and the laboratory responsible for the final determination.
Common Interpretation Errors
- Citing FAO compliant without naming the specification, manufacturer scope or test clauses.
- Listing a CIPAC method without an acceptance limit.
- Comparing results reported on different concentration bases or with different method versions.
- Assuming a specification confirms efficacy, registration or suitability for every crop and market.
Use these principles alongside the pesticide formulation quality document guide to connect contract requirements with the COA, product specification and retained sample.
A Practical Procurement Record
Record the agreed specification, test method and acceptance limit in the purchase file before a sample or batch is evaluated. The quotation, specification, certificate of analysis, safety data sheet, label artwork and packaging description should identify the same product configuration. If one document changes, check whether the others must be revised as well.
A laboratory result is meaningful only when the sample identity, batch number, sampling point, method version, units and acceptance criterion are traceable. Buyers should not compare two numbers merely because the parameter names look similar. Different methods, sample preparation or reporting bases can produce results that are not directly comparable.
Build the approval record before the purchase order is released. It should identify who approved the specification, which laboratory may perform release and dispute tests, how retained samples will be stored, and what happens when a result falls outside the agreed limit. The process should distinguish a confirmed failure from a sampling, method or transcription problem while keeping questioned stock under control.
Change control is equally important after approval. A new manufacturing source, formulant, concentration basis, package material, test method or label may alter the evidence needed for comparison. Require the supplier to notify the buyer before the change, then document whether fresh regulatory review, stability data, specification approval or customer acceptance is required.
Before final approval, ask a second reviewer to reconcile the technical conclusion with the actual purchase specification and proposed label. Independent review often catches unit differences, outdated methods, missing source identity and limits copied from the wrong formulation type.
This guide supports supplier qualification and document review. It does not replace a registered label, national pesticide law, a competent laboratory assessment or advice from a qualified local agronomist or regulatory specialist.
Frequently asked questions
Is an FAO/WHO specification a pesticide registration?
No. It is a quality reference. Registration and permitted uses remain subject to the competent authority and approved label.
What is the difference between a specification and a CIPAC method?
The specification states the required property and limit. The CIPAC method states how the property is tested or measured.
Can a supplier claim FAO compliance for any manufacturing source?
Not automatically. Check whether the relevant specification uses the new procedure and whether the manufacturer's data were evaluated within its scope.
Authoritative references
- Pesticide Specifications - Food and Agriculture Organization of the United Nations
- Pesticide Specifications in the Registration Toolkit - Food and Agriculture Organization of the United Nations
- CIPAC Methods and Publications - Collaborative International Pesticides Analytical Council
